Current Draw

As a diagnostic tool, measuring current consumption can identify latent problems in sensors and help maintain your network. The ZSC provides active and sleep states for testing sensors. Refer to the table below for typical maximum current values for each sensor type.

Sensors with current draw above the maximum or an order of magnitude greater than the typical current have internal electronic problems and should be removed from the network and replaced.

ATMOS

Minimum

Typical

Maximum

Notes

ATMOS 41

Link

Awake

0.2 mA

8.0 mA

33.0 mA

Asleep

0.2 mA

0.03 mA

0.4 mA

ATMOS 22

Link

Awake

0.2 mA

8.0 mA

33 mA

Asleep

0.2 mA

0.3 mA

0.4 mA

ATMOS 14

Link

Awake

3.0 mA

3.5 mA

9.9 mA

Asleep

N/A

0.03 mA

N/A

TEROS

Minimum

Typical

Maximum

Notes

TEROS 6

Link

Awake

2.0 mA

2.5 mA

4.0 mA

Asleep

N/A

80.0 uA

N/A

TEROS 12

Link

Awake

3.0 mA

3.6 mA

16 mA

Asleep

N/A

0.03 mA

N/A

TEROS 11

Link

Awake

3.0 mA

3.6 mA

16 mA

Asleep

N/A

0.03 mA

N/A

TEROS 21

Gen1 Link

Gen 2 Link

Awake

3.0 mA

5.0 mA

16.0 mA

*Gen 2

Asleep

N/A

0.03 mA

N/A

*Gen 2

TEROS 32

Link

Awake

18 mA

25 mA

30 mA

Asleep

0.03 mA

0.05 mA

0.90 mA

HYDROS

Minimum

Typical

Maximum

Notes

HYDROS 21

Link

Awake

0.5 mA

0.5 mA

1.0 mA

Asleep

N/A

0.3 mA

N/A

LEGACY

Minimum

Typical

Maximum

Notes

5TE

Link

Awake

0.5 mA

3.0 mA

10 mA

Asleep

N/A

0.03 mA

N/A

5TM

Link

Awake

0.5 mA

3 mA

10 mA

Asleep

N/A

0.03 mA

N/A

GS3

Link

Awake

0.5 mA

3.0 mA

30 mA

Asleep

N/A

0.03 mA

N/A

10Hs

Awake

0.5 mA

12 mA

20 mA

Link

Asleep

N/A

0.03 mA

N/A