Data Collection & Telemetry
Overview
Update Hardware
Module and SIM Update Guides
Module Identification
Module Swap Wizard
SIM Swap Wizard
AT&T / T-Mobile Configuration Guide
Verizon Configuration Guide
Worldwide H1 SIM Configuration Guide
SIM Replacement Instructions
Wi-Fi Configuration Guide
Firmware Update
Troubleshoot
ZL6 Troubleshooting Guide
Communication Test
Test Button & Status Lights
List Cellular Carriers
ATMOS 41W
EM60G
EM50G
Fix: Retroactively Enable LTE-M Bands for 4G in Europe
Coverage
Accessories
ZENTRA Cloud 1.0 (Classic)
Quick Start
Organizations
Account
Edit Account Profile
Update Account Password
Lost Password/Password Reset
Set Measurement Unit Preferences
Users
Devices
Device Inventory
Edit Device
Re-provision ZL6 to European Server
Add Device
Remove Device
Time-zone and Location Override
Calibrations
Downloads
Dashboard
Enable Chart Status
Create Custom Charts
Color Picklist
Add Traces to Chart
Chart Stats
Print Charts
Set a Target Range
Lock Chart Axes
Chart Date Range Picker [NEW]
Download Chart Data
Notifications
Models
Daily Light Integral
Ground Water Elevation
Ground Water Depth
Plant Available Water
Daily Light Photoperiod
Chill Hours
Growing Degree Days
Create a Model
Evapotranspiration
Subscriptions
API
US Server API
EU Server API
TAHMO Server API
Push API
R Package
API Troubleshoot
AgWeatherNet & DAS
Manage API Keys
Error Codes
Applications
FAQ
Accessibility
Release Notes
ZENTRA Field
ZENTRA Cloud 2.0 (Beta)
Getting Started
User Account
Setup
Devices
Add Data Logger
Configure Data Logger
Device Map
Data Logger Charts
Download Data Logger
Logs
Archive
Dashboards
Explorer
Data
Projects
Alerts
Environment Models
Groundwater Elevation [2.0]
Groundwater Depth [2.0]
Chill Hours [2.0]
Utah Chill Model [2.0]
Growing Degree Days [2.0]
Heat Index [2.0]
Heat Stress Wet Bulb Globe Temperature WBGT [2.0]
Wind Chill [2.0]
Evapotranspiration [2.0]
Leaf Wetness Amount of Water [2.0]
Daily Light Photoperiod [2.0]
Plant Available Water [2.0]
Daily Light Integral [2.0]
ZENTRA Cloud Beta Release Notes
Accessibility
Feedback
Privacy, Security, Terms & Conditions
Uptime Monitor
Table of Contents
- All Categories
- Data Collection & Telemetry
- Troubleshoot
- Test Button & Status Lights
Test Button & Status Lights
Pressing the TEST button initiates the self-test sequence.
Pressing the TEST button initiates the self-test sequence. The self-test can take 60 seconds or more if testing communications over the cellular network. The following actions are part of the self-test sequence:
Test Button
- Reboots the data logger.
- This ensures internal software restarts and is operating in an expected way. Both status lights stay lit during the reboot. This reboot will not erase data or reset settings.
- Perform basic functionality testing on internal systems and evaluate the amount of charge in the battery.
- Both the green and red lights blink together slowly while the logger performs tests.
- Autodetects connected digital sensors.
- Starts the embedded GPS receiver to obtain a current time and location fix.
- This process takes as long as 15 minutes to complete.
- Establish an internet connection over the network (cellular, Wi-Fi, etc) and communicate with ZENTRA Cloud.
- Enable the Bluetooth module to allow connection with ZENTRA Utility Mobile.
After completing the self-tests, the data logger will indicate success or failure by lighting either the red or green status light.
A solid green light (for approximately 20s) indicates that internal tests passed and, if applicable, there is successful communication over the network.
A solid red light indicates an error in the logger, which may indicate:
- Corrupt logger firmware.
- Low battery power.
- Unsuccessful communication over the network.
Use ZENTRA Utility to identify where the self-tests may have failed or to troubleshoot further.
Status Lights
The lights near the TEST button indicate the status of the data logger. The green light is labeled OK and the red light is labeled ERROR.
Lights | Status Description |
The green light gives a short, single blink every 5 seconds. | The device is logging sensor data |
The green light blinks slowly (1 second on, then 1 second off). | The device is communicating with the network or ZENTRA Utility |
The green and red lights are blinking together |
|
The measurement interval is set to "Off (not logging)" | The lights remain off |
The red light stays on solid | Contact Support |